Belden 88777 Cable Equivalent, FEP-TFE-PTFE, Price $750/1000 ft.
Detailed Specifications and Technical Data

Description: 22 AWG stranded (7x30) TC conductors, FEP insulation, three individually twisted shielded pairs, foil shield (100% coverage), 22 AWG stranded TC drain wire, FEP jacket - Red. Plenum Rated CMP.

Physical Characteristics:
BELDEN 88777 CABLE
CONDUCTOR:
PRICE $750/1000 ft.

Number of Pairs 3
Total Number of Conductors 6
AWG 22
Stranding 7x30
Conductor Material TC - Tinned Copper
BELDEN 88777 CABLE INSULATION:
Insulation Material FEP - Fluorinated Ethylene Propylene
Nom. Insulation Wall Thickness .007 in.
Lay Length 1.5 in.
Twists/ft. 8
Pair Color Code Chart:
Number: 1
Number: 2
Number: 3

Black & Red
Black & White
Black & Green
BELDEN 88777 OVERALL CABLING:
Overall Cabling Separator Material Polyester tape
Overall Cabling Separator Thickness 0.001 in.
BELDEN 88777 CABLE INNER SHIELD:
Inner Shield Type Tape
Inner Shield Material Aluminum Foil-Polyester Tape
Inner Shield % Coverage 100%
BELDEN 88777 CABLE INNER SHIELD DRAIN WIRE:
Inner Shield Drain Wire AWG 22
Inner Shield Drain Wire Stranding Stranded
Inner Shield Drain Wire Conductor Material TC - Tinned Copper
BELDEN 88777 CABLE OUTER JACKET:
Outer Jacket Material FEP - Fluorinated Ethylene Propylene
Outer Jacket Nominal Wall Thickness .014 in.
BELDEN 88777 CABLE OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter .234 in.
BELDEN 88777 CABLE MECHANICAL CHARACTERISTICS:
Operating Temperature Range -70°C To +200°C
Bulk Cable Weight 38.9 lbs/1000 ft.
Max. Recommended Pulling Tension 82 lbs.
Min. Bend Radius (Install) 2.3 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
BELDEN 88777 CABLE APPLICABLE STANDARDS:
NEC/(UL) Specification CMP
CEC/C(UL) Specification CMP
EU CE Mark (Y/N) Yes
EU RoHS Compliant (Y/N) Yes
BELDEN 88777 CABLE FLAME TEST:
UL Flame Test NFPA 262
C(UL) Flame Test FT6
BELDEN 88777 CABLE SUITABILITY:
Suitability - Indoor Yes
Suitability - Outdoor Yes
Suitability - Burial Yes
Oil Resistance Yes
BELDEN 88777 CABLE ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance 50 Ohms
Nom. Inductance .18 £gH/ft
Nom. Capacitance Cond. to Cond. @ 1 KHz 31 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 67 pF/ft
Nominal Velocity of Propagation 69 %
Nominal Delay 1.47 ns/ft
Nom. Conductor DC Resistance @ 20°C 16 Ohms/1000 ft
Nom. Outer Shield DC Resistance @ 20°C 11.3 Ohms/1000 ft
Max. Operating Voltage - UL 300 V RMS
Max. Recommended Current 1.96 Amps per conductor @ 25°C
NOTES: For use in indoor plenum environments but also suitable for outdoor and underground applications.

PUT-UPS AND COLORS - ALL SPOOLS ARE CONTINUOUS LENGTHS
88777 Cable
$750/1000 ft.
Put-Up (ft.) Ship Weight Jacket Color
88777 Cable 1000 39 lbs. RED
88777 Cable 2000 78 lbs. RED
88777 Cable 2500 97 lbs. RED
88777 Cable 3000 117 lbs. RED
88777 Cable 5000 195 lbs. RED


PlenumCable1.com is a division of WorldWideWire.com.

Home Page

PHONE: (760) 832-1798 - FAX: (760) 328-9830
www.plenumcable1.com